InstallatIon- lInearNote: Prior to installing positioner, ensure all safety precautions have been taken.- All input or supply pressure to valve, ac
-10-terMInal overvIew and ConneCtIons, ContInuedGround:1. Prior to operating the positioner, please ensure that it has been properly grounded.2. Ope
-11-adjustMentsLimit Switch Adjustments1. HIGH variable resistor adjusts the sensing point of the valve end point. For Direct Acting, it will sense 4
-12-operatIonThe following process will operate the valve and actuator. Prior to proceeding with any AUTO Calibration please isolate the valve and act
-13-operatIon, ContInuedAuto Calibration:The Auto Calibration mode (AUTO CAL) will automatically calibrate the positioner. The AUTO CAL process will t
-14-operatIon, ContInuedAUTO3 Calibration Mode:AUTO3 will only change the valve parameters. Zero and End Point adjustments will not be made.Manual Mod
-15-operatIon, ContInueddEAdZONE – Deadzone mode:dEAdZONE mode indicates the percentage of error allowance. In cases of high level packing friction, w
-16-operatIon, ContInuedD1 Value – (Kd1):D Value indicates the derivative value of the compensation signal, based on the percentage of error allowance
-17-operatIon, ContInuedPeriod T:Period T indicates the positioners internal control time interval. By default the Mark 17X will check the current pos
-18-operatIon, ContInued*Hand Calibration Mode (HAND CAL):The Mark 17X may be manually calibrated by selecting the Hand Calibration Mode.Zero Point (P
-19-operatIon, ContInuedZero Point (TR_ZERO) and End Point (TR_END) for transmitter:TR_ZERO will adjust the zero point of the transmitter (4-20mA feed
Mark 17X SerieS FlaMeprooF SMart poSitionerS-2-Linear Installation, Continued2. Attach the positioner and mounting bracket to the actuator yoke
-20-operatIon, ContInuedNormal / Reverse Feedback Signal (TR_NORM/REV):The feedback signal from the positioner may be set as normal or reverse.Normal/
-21-operatIon, ContInued*Valve Mode (VALVE)Acting Adjustments (ACT):The positioner may be set as Direct Acting (DA), or Reverse Acting (RA).Characteri
-22-operatIon, ContInuedUser Characteristics (USER SET):Should the positioner require a specific characteristic, the valve characteristic curve can be
-23-operatIon, ContInuedTight Shut Close (TSHUT CL):Tight Shut Close allows the valve to close completely as the input signal reaches 4mA.Split Range
-24-operatIon, ContInuedCustom End Setting Mode (CST ENd):The Custom End Setting Mode allows the user to set any specific point as the end position. Fo
-25-operatIon, ContInuedView Mode (VIEW):View Mode displays positioner information on the LCD.Display Description2600L Positioner ModelVERSION Main So
-25-error and warnIng CodesError code Code Description and Cause ActionMT ERR L - Positioner is improperly installed- Positioner is not level to the g
MaIn software MapJordan Valve, a division of Richards Industries 3170 Wasson Road • Cincinnati, OH 45209 513.533.5600 • 800.543.7311 • 513.871.
-3-Bracket Information:The supplied standard bracket contains two com-ponents. The bracket may be used for both fork lever type and NAMUR lever type c
-4-4. Install the fork lever after setting the actuators stem at 0%. Check the actuator stem rotation direction, clockwise or counter clock
-5-7. Tighten the positioner and the bracket using the hex head bolts and plate washers, after checking for proper alignment and position of the
ConneCtIonsSupply:Supply pressure should be clean, dry air. Avoid moisture, oil and dust. It is recommended that a filter regulator be used as part of
-7-ConneCtIons, ContInuedConnection: Double Acting Actuator,Double acting type positioner is set to use the OUT1 and OUT2 ports. As the input signal i
-8-terMInal overvIew and ConneCtIonsPositioner Terminal:IN + : Input Signal (positive) IN - : Input Signal (negative)OUT + : Feedback Signal (positi
-9-Feedback Signal Terminal:1. Open terminal cover by removing set screw using a 3mm hex key2. There are two conduit entries on the bottom side of t